In
the Oil & Gas and Offshore industry where combustible gasses are available,
it is important to alter these sorts of pipe leaks and pipe imperfections with
cold curing repair. This is due to the fact that hot works are by and large
precluded.
Composite
repair framework utilizing composite wrap must meet the base prerequisites and
perform at the normal level under compelling conditions. Various composite
repair materials are accessible on the open market today, however there are few
that have the testing and capacity to perform at the raised temperatures which
may be experienced.
Gathering Pipeline Data & Information
At
the point of performing online pipe leak repairs, it is important to follow in
agreement to ASME PCC2 and ISO 24817 guidelines and necessities. All
information for the pipeline working pressure, temperature, pipe size and pipe
medium ought to be accumulated and analysed.
Point by point Engineering Calculation and Application Method of Statement
A
point by point engineering calculation and report particularly targeted towards
the pipe leak must be created to decide the amount and kind of materials to be
utilized. The strategy for application itemizing an orderly repair method might
be given and endorsed by the customer.
Site
study ought to be led before work initiation, so all dangers are evaluated and analysed
into danger evaluation report. All Personnel Protective Equipment ought to be
worn and danger alleviating/ decreasing steps utilized to minimize or stay away
from every single superfluous danger.
Surface Preparation of Affected Pipe Section
Before
work begins, consistently attempt to stop or lessen the pipeline pressure and
temperature to the maximum ability. Beginning surface readiness by utilizing
the grit blasting technique – sanitise affected pipe surface to SA 2.5 standard
at when possible. At areas where grit blasting is impractical, these areas
should be sanitised with proper non-spark apparatuses. The length of surface
planning ought to be in agreement to the Engineering Calculation Report given.
While performing surface planning, pipe surface ought to stay dry throughout
the procedure. Set up the pipe surface roughness to about 60 to 80 microns.
Utilize a surface roughness analyzer to affirm the arranged surface roughness
has been accomplished.
Initiation of Pipe Leak Repair Works
Initiation
of pipe repair technique – pipe leak repair procedure ought to start within 4
hours after the surface arrangement has been finished. Prior of starting of pipe
repair works, make sure the leak area is appropriately checked.
Use
the latex gloves and manipulate enough quantity of SS106 Seal Stic underwater
epoxy stick to cover the range of the leak. Put the blended Seal Stic onto a
stainless steel sheet metal. Then, set up a few packs of SealXpert stainless
steel clip by cutting a fitting length of the steel clip. Join the cut-off
length of stainless steel clip with movable fasteners. Wrap the connection with
movable fastener with a PVC tape. Put the stainless steel backing against the
SealXpert stainless steel clip while the Seal Stic faces the pipe surface, away
from the leak area. Tighten the movable fastener of SealXpert stainless steel
clip a little and slide the few sets of clip to the leak area. These SealXpert
stainless steel clips ought to be situated by one another, securing both the center
and edge of leak area. Keep on
tightenning the movable fastener of SealXpert stainless steel clip while
guaranteeing that the Seal Stic is protecting the leak opening.
Remaking of Affected Pipe Section
When
the leak is captured, use SealXpert PS102 metal repair putty. Blend the
hardener part of PS102 metal repair putty into the resin bowl and use the
blended repair putty over the arranged pipe area. The thickness of the coat ought
to be in agreement to the Engineering Calculation Report given. Permit the
covered SealXpert PS102 repair putties to cure for enough time and look out for
the condition of the leak. Utilize a barcol hardness analyzer to affirm the
cured putty has acquired at least 85 Shore D hardness.
Composite Pipe Wrapping
Use
the latex gloves and open the Wrap Seal PLUS fiberglass repair tape and
submerge it in water for 10 seconds; crush the roll while submerging it in
water. Take off the fiberglass tape from the water and begin wrapping the Wrap
Seal PLUSTM fiberglass repair tape. The wrapping of fiberglass tape
ought to begin no less than 100mm to 200mm preceding the leak region. Wrap the
pipe as hard and equitably as could be expected under the circumstances,
pulling marginally after each round of wrapping. Use the whole roll over the pipe
surface with no less than 50% overlap for the whole pipe repair length. All length
of wrapping ought to be in agreement to Engineering Calculation Report. Repeat
the wrapping for a particular number of layers of Wrap Seal Plus fiberglass
repair tape and lastly tapering off with about 25mm over every wrapping layer.
The wrapping ought to be done in one direction.
Examination of Repair
Permit
the repaired zone to be cured for a few hours (length of time is reliant on
pipeline working condition). Analyse to affirm the last Barcol hardness
estimation.
Repair
work is finished and the repaired framework can be worked back to typical
working condition.
Tidak ada komentar: